Serranator serration balloon catheter

Serranator

The ONLY angioplasty balloon with Serration Technology delivering optimal lumen expansion at lower pressures, with predictable results, minimal dissection, and sustained patency.

Peripheral artery disease demands more than conventional balloon angioplasty can reliably offer. The Serranator changes the equation. Powered by Serration Remodeling Therapy™ (SRT), it applies focused point force along the arterial wall to create micro-fissures that release the internal elastic lamina, opening even complex, calcified lesions without the unpredictability of plain old balloon angioplasty (POBA).

0

Freedom from CD-TLR at 6 months (PRELUDE ATK)

0

Avg recoil compared to 55% with POBA (RECOIL Study)

0

Bailout stent rate (PRELUDE BTK)

The Data Speaks For Itself

Why SRT?

It’s Time for a New Standard of Care

Plain old balloon angioplasty has defined peripheral intervention for decades, but its limitations are well-documented. High rates of recoil, unpredictable dissection, and the need for bailout stenting compromise outcomes and add procedural complexity.

Serration Remodeling Therapy doesn’t improve on POBA.
It replaces the mechanism entirely.

POBA Serranator
Mechanism Circumferential stretch Controlled point-force serration
Recoil High (avg. 55%) Low (avg. 6%)
Dissection risk Unpredictable Minimized via controlled serrated line
Pressure required 9ATM avg. 5ATM avg.
Lesion morphology Limited efficacy in calcification Effective across all morphologies
Icon representing Serranator PTA serration balloon catheter ordering information

Ordering Information

Serranator PTA Serration Balloon Catheter

Available in a comprehensive range of diameters (2.5–8.0 mm) and lengths (40–120 mm) to address the full spectrum of peripheral lesion anatomy. Refer to the product label and package insert for complete warnings, precautions, and instructions for use.

View Brochure, Reimbursement Information, Instructions for Use (IFU)

REF GTIN BALLOON
DIAMETER (MM)
BALLOON
LENGTH (MM)
GUIDEWIRE
COMPATIBILITY
(MM)
SHEATH SIZE (F) CATHETER
LENGTH (CM)
FGS-0346-25040008524950080982.5400.014"6150
FGS-0346-25080008524950081042.5800.014"6150
FGS-0346-25120008524950081112.51200.014"6150
FGS-0346-30040008524950081283.0400.014"6150
FGS-0346-30080008524950081353.0800.014"6150
FGS-0346-30120008524950081423.01200.014"6150
FGS-0346-35040008524950081593.5400.014"6150
FGS-0346-35080008524950081663.5800.014"6150
FGS-0346-35120008524950081733.51200.014"6150
FGS-0492-40040008524950080054.0400.018"6150
FGS-0492-40120008524950080294.01200.018"6150
FGS-0492-50040008524950080365.0400.018"6150
FGS-0492-50120008524950080505.01200.018"6150
FGS-0492-60040008524950080676.0400.018"6*150
FGS-0492-60120008524950080816.01200.018"6*150
REF GTIN BALLOON
DIAMETER (MM)
BALLOON
LENGTH (MM)
GUIDEWIRE
COMPATIBILITY
(MM)
SHEATH SIZE (F) CATHETER
LENGTH (CM)
FGS-0898-7040008524950085177.0400.018"6*110
FGS-0898-8040008524950085248.0400.018"7110
REF GTIN BALLOON
DIAMETER (MM)
BALLOON
LENGTH (MM)
GUIDEWIRE
COMPATIBILITY
(MM)
SHEATH SIZE (F) CATHETER
LENGTH (CM)
FGS-1004-6040008524950085866.0400.018"6*70
FGS-1004-7040008524950085937.0400.018"6*70
FGS-1004-8040008524950086098.0400.018"770

*6F compatible with sheath IDs ≥ 0.087" (2.2 mm)

bring SRT and Serranator to your Center

Data provided by 

Guetl K, Muster V, Schweiger L, Tang WC, Patel K, Brodmann M. Standard Balloon Angioplasty Versus Serranator Serration Balloon Angioplasty for the Treatment of Below-the-Knee Artery Occlusive Disease: A Single-Center Subanalysis From the PRELUDE-BTK Prospective Study. J Endovasc Ther. 2024 Aug;31(4):615-621. doi: 10.1177/15266028221134891. Epub 2022 Nov 20. PMID: 36408609.

Fereydooni A, Chandra V, Schneider PA, Giasolli R, Lichtenberg M, Stahlhoff S. Serration Angioplasty Is Associated With Less Recoil in Infrapopliteal Arteries Compared With Plain Balloon Angioplasty. J Endovasc Ther. 2025 Oct;32(5):1600-1606. doi: 10.1177/15266028231215284. Epub 2023 Dec 7. PMID: 38059463.

Fanelli F, Cannavale A, Gazzetti M, Lucatelli P, Wlderk A, Cirelli C, d'Adamo A, Salvatori FM. Calcium burden assessment and impact on drug-eluting balloons in peripheral arterial disease. Cardiovasc Intervent Radiol. 2014 Aug;37(4):898-907. doi: 10.1007/s00270-014-0904-3. Epub 2014 May 9. PMID: 24806955.